Installation of radar liquid level sensors and control systems

With the rapid development of industrial automation, the application of radar level sensors and control systems is becoming increasingly widespread. Radar liquid level sensors use electromagnetic waves to detect liquid levels, which have advantages such as high measurement accuracy, good stability, and low environmental requirements. The control system is responsible for collecting, processing, controlling, and outputting signals from radar level sensors, ensuring the stable operation of the entire system. This article will focus on the installation steps and precautions of radar liquid level sensors and control systems.

1、 Installation of radar liquid level sensor

Before installing the radar level sensor, it is necessary to determine the appropriate installation location. Generally, it is recommended to install it at the center of the storage tank to avoid interference sources such as the inlet, outlet, and agitator. At the same time, it is necessary to ensure that there are no obstructions between the sensor and the liquid level to avoid affecting measurement accuracy.

Choose appropriate installation brackets and lifting components based on the height of the storage tank and the weight of the sensors. Ensure that the brackets and lifting components are firm and reliable, and can withstand the weight of the sensors. At the same time, it is necessary to ensure that the positions of the brackets and lifting components are reasonable for subsequent debugging and maintenance.

Install the radar liquid level sensor on the bracket, adjust the height of the sensor to keep it parallel to the liquid level. At the same time, it is necessary to ensure that the sensor is kept at a certain distance from the bottom of the storage tank to avoid interference from impurities at the bottom. During the installation process, pay attention to protecting the cables and connectors to avoid damage or moisture.

Connect the cable of the radar level sensor to the control cabinet or instrument panel, paying attention to the matching of the connection method and voltage level. At the same time, it is necessary to do a good job in fixing the cables to prevent them from loosening or being squeezed by external forces.

2、 Installation of control system

Determine the location of the control cabinet or instrument panel based on the actual situation on site, and choose a suitable location to install the control cabinet or instrument panel. To ensure that the control cabinet or instrument panel is easy to operate and maintain, while taking into account safety, dust, moisture, and other requirements.

Install power and signal cables to provide stable power supply for the control system, and connect the signal cables properly. Signal lines generally use shielded cables to reduce the impact of electromagnetic interference. When connecting signal lines, ensure that the connectors are firm and reliable to avoid problems such as poor contact or short circuits.

Install control software and debug according to actual needs, select appropriate control software, and install it on the control cabinet or instrument panel. During the installation process, pay attention to software version compatibility and operating system requirements. After installation, debug the control system to ensure it can function properly and achieve the expected control effect.

3、 Precautions

During the installation process, it is necessary to strictly comply with relevant safety regulations and operating procedures to ensure the safety of personnel and equipment.

Before installation, the equipment should be inspected and tested to ensure its performance is normal and undamaged. At the same time, it is necessary to check whether the installation location and environment meet the requirements.

During the installation process, pay attention to protecting the cables and connectors to avoid damage or moisture. At the same time, ensure that the connection is firm and reliable, and avoid problems such as poor contact or short circuits.

During the debugging process, it is necessary to set the various parameters of the control system reasonably and adjust and optimize them according to actual needs. At the same time, relevant records and backup work should be done well.


主图8


Home
WEIHAI KUNKE FLOW INSTRUMENT CO.,LTD. is a high-tech enterprise specialized in instrument research and development, production, sales and service.

Product Category

Contact Us

Contact Us

  kunke@whliuliangji.com

+86-18660356923

 +86-15725618973

  +86-15725618973

Leave a Message
Contact Us
Copyright © 2022 Weihai Kunke Flow Instrument Co.,ltd. All rights reserved. Privacy Policy | Sitemap | Support By Leadong