Availability: | |
---|---|
Quantity: | |
Hot sell Open channel water ultrasonic flow meter with 4-20mA
In industrial production and agricultural production, it is necessary to measure the flow of some ditches, and open channel flow tanks are required at this time. Open channel flow trough: the waterway flowing in the non-full pipe state is called open channel flowmeter. The application places of the open channel flowmeter include urban water supply diversion channels, thermal power plant cooling water diversion and drainage channels, sewage treatment inflow and discharge channels, industrial and mining wastewater discharge, and water conservancy projects and agriculture. irrigation channels.
Ultrasonic open channel flowmeter | |
Structure: | Unibody and split body |
Measuring range : | 0.1m³/h-99999.99m³/h, according to different weir groove decision |
Cumulative flow: | up to 429000000.00m³ |
Accuracy of liquid level measurement : | 0.5% |
Resolution : | 3mm or 0.1%(whichever is larger) |
Flow measurement accuracy: | standard weir groove 1-5% |
Power supply : | 220V/24V/12V, battery power supply, solar power supply, etc |
Protection level: | display instrument IP66, probe IP68 |
Doppler open channel flowmeter | |
Water level measurement range (m): | 0.02~3m, 0.02~10m |
Flow rate range : | 0.03m/s~5.0m/s |
Measurement resolution : | 1mm/s |
Measuring accuracy: | system error ±3‰ |
Flow measurement range : | 1 L/s ~99999999m3/h |
Operating temperature (℃): | -20℃~+60℃ |
Minimum water level resolution (mm): | ±1mm |
Signal output: | RS485, MODBUS protocol |
Power supply: | DC12V, battery power, solar power, etc |
Multichannel open channel flowmeter | |
Measurement velocity accuracy : | 1.0% |
Flow rate range : | ±10m/s |
Measuring channel width: | time difference method 0.5~10 meters |
Time difference measurement resolution : | 40 picoseconds |
Ambient temperature : | -20~70℃ |
Medium temperature : | -20~80℃ |
Protection level : | IP68 |
Hot sell Open channel water ultrasonic flow meter with 4-20mA
In industrial production and agricultural production, it is necessary to measure the flow of some ditches, and open channel flow tanks are required at this time. Open channel flow trough: the waterway flowing in the non-full pipe state is called open channel flowmeter. The application places of the open channel flowmeter include urban water supply diversion channels, thermal power plant cooling water diversion and drainage channels, sewage treatment inflow and discharge channels, industrial and mining wastewater discharge, and water conservancy projects and agriculture. irrigation channels.
Ultrasonic open channel flowmeter | |
Structure: | Unibody and split body |
Measuring range : | 0.1m³/h-99999.99m³/h, according to different weir groove decision |
Cumulative flow: | up to 429000000.00m³ |
Accuracy of liquid level measurement : | 0.5% |
Resolution : | 3mm or 0.1%(whichever is larger) |
Flow measurement accuracy: | standard weir groove 1-5% |
Power supply : | 220V/24V/12V, battery power supply, solar power supply, etc |
Protection level: | display instrument IP66, probe IP68 |
Doppler open channel flowmeter | |
Water level measurement range (m): | 0.02~3m, 0.02~10m |
Flow rate range : | 0.03m/s~5.0m/s |
Measurement resolution : | 1mm/s |
Measuring accuracy: | system error ±3‰ |
Flow measurement range : | 1 L/s ~99999999m3/h |
Operating temperature (℃): | -20℃~+60℃ |
Minimum water level resolution (mm): | ±1mm |
Signal output: | RS485, MODBUS protocol |
Power supply: | DC12V, battery power, solar power, etc |
Multichannel open channel flowmeter | |
Measurement velocity accuracy : | 1.0% |
Flow rate range : | ±10m/s |
Measuring channel width: | time difference method 0.5~10 meters |
Time difference measurement resolution : | 40 picoseconds |
Ambient temperature : | -20~70℃ |
Medium temperature : | -20~80℃ |
Protection level : | IP68 |