What Are The Calibration Methods for Flowmeters? The Results Are All Here

Flowmeters are commonly used measurement tools in the industrial field for monitoring and controlling fluid flow. Regular calibration is essential to ensure the accuracy and reliability of the flow meter. This article will introduce several common calibration methods for flow meters.


1、 Comparison method for standard flow meters


The comparison method of standard flow meters is one of the most commonly used calibration methods. This method uses a highly accurate standard flow meter, which is connected in series with the calibrated flow meter in the same pipeline, to allow the fluid to pass through both flow meters. By comparing the readings of the two, the error of the calibrated flow meter can be determined. This method is suitable for various types of flow meters and has advantages such as high accuracy and easy operation.


2、 Standard volume container method


The standard volume container method is a direct calibration method suitable for calibrating liquid flow rates. This method uses a standard volumetric container, connects the calibrated flow meter to the volumetric container, and records the reading of the flow meter and the actual volume of the volumetric container. By comparing the two data, the error of the flow meter can be calculated. The standard volume container method has high accuracy, but requires the use of precision measuring equipment.


3、 Quality Law


The quality method is a direct calibration method suitable for calibrating gas flow rates. This method uses a precision balance to measure the mass of gas and a flow meter to measure the volume of gas. By comparing mass and volume data, the error of the flow meter can be calculated. The quality method has high accuracy, but requires the use of precision balance equipment and complex operation.

4、 Standard Table Method

The standard meter method is an indirect calibration method suitable for various types of flow meters. This method uses a highly accurate standard flow meter as the standard meter, and the calibrated flow meter is connected in parallel with the standard meter to allow the fluid to pass through two flow meters. Record the readings of the calibrated flow meter and standard meter, and then calculate the error of the calibrated flow meter based on the known standard meter error. The standard table method is easy to operate and suitable for online calibration.

In summary, the above four methods are common calibration methods for flow meters. In practical applications, appropriate calibration methods should be selected based on specific circumstances to ensure the accuracy and reliability of the flow meter.




Home
WEIHAI KUNKE FLOW INSTRUMENT CO.,LTD. is a high-tech enterprise specialized in instrument research and development, production, sales and service.

Product Category

Contact Us

Contact Us

  kunke@whliuliangji.com

+86-18660356923

 +86-15725618973

  +86-15725618973

Leave a Message
Contact Us
Copyright © 2022 Weihai Kunke Flow Instrument Co.,ltd. All rights reserved. Privacy Policy | Sitemap | Support By Leadong